Project Information

Wall U-value limit: Normal (≤ normal limit, 80% reduction if embedded system selected)
Climate Zone Selection
IMPORTANT - Select your zone. Zone 7A is pre-selected.
Zone Limits & Information

Zone 7A Limits:

  • Opaque walls: ≤ 0.215 W/(m²·K)
  • Roofs: ≤ 0.121 W/(m²·K)
  • Exposed Floors: ≤ 0.138 W/(m²·K)
Part 3 - Building Envelope – NECB Section 3.2
Area Calculations (m²)
Sum of all wall areas including fenestrations & door. Exclude parapets, ornamentation... (Table 3.1.1.6.3)).
FDWR for HDD: 5700 (Zone 7A)
0.0%
Enter values to calculate FDWR
Include doors with < 50% glazed area.
Directly adjacent exposed floors
Gross roof area includes skylights & roof hatches.
Skylight-to-Roof Ratio (SRR) 0.0%
< 2% of gross roof area per 3.2.1.4.(2)
Above-ground U-Values (W/(m²·K))
W/(m²·K)
Per Table 3.2.2.2
Zone limit: 0.215 W/(m²·K)
W/(m²·K)
Per 3.2.3.2.
Zone limit: 0.121 W/(m²·K)
W/(m²·K)
Per Table 3.2.3.3.
Zone limit: 0.138 W/(m²·K)
W/(m²·K)
Per Table 3.2.2.3.
Zone limit: 1.73 W/(m²·K)
In Contact w/ Ground U-Values (W/(m²·K)))
W/(m²·K)
Max U-value @ ≤ 1.2m below ground
Zone limit: ≤ W/(m²·K)
W/(m²·K)
Located ≤ 1.2m below ground
Zone limit: ≤ W/(m²·K)
W/(m²·K)
Per NECB 3.2.3 requirements
Zone limit: ≤ 0.757 W/(m²·K)
               
 
Air Leakage (L/(s·m²))

FENESTRATIONS

L/(s·m²)
Per 3.2.4.3.(2) & 3.2.4.3.(3)
L/(s·m²)
Per 3.2.4.3.(4)

DOORS

L/(s·m²)
Exception per 3.2.4.3.(2)
L/(s·m²)
Limit increased to 14 L/(s·m²) if door is ≤ 2% of gross wall area, per 3.2.4.3.(4)
W/(m²·K)
Per 3.2.2.4.(4)
For information only
L/(s·m²)
Limit: ≤ 0.20 L/(s·m²) @ 75 Pa. Continuous air barrier required per 3.2.4
For information only
m
3.2.3.1.(3) - Min. 2.4m from ground
For information only
m
3.2.3.1.(5) - If <0.6m, insul. 1.2m perimeter insul For information only
FDWR Calculation (HDD-Based)
5700 HDD (Zone 7A default)
Formula: (2000 - 0.2 × 5700) / 3000 = 28.7% max
CALCULATING...
0.0%
Formula: Enter values above to calculate
FDWR Progress Max: 28.7%
0% 0% 28.7%
NECB 3.2.1.4 Formulas:
• HDD ≤ 4000: FDWR = 40%
• 4000 < HDD < 7000: FDWR = (2000 - 0.2 × HDD) / 3000
• HDD ≥ 7000: FDWR = 20%
Detailed Compliance Check
Component Proposed NECB Limit Status
AI-Assisted Analysis

No analysis has been generated. Click "Analyze with AI" or "Configure AI to Analyze" to begin.

AI-Assisted Analysis
Compliance Path Options
Data Management
Warning: This will erase all input values. Data is automatically saved as you type.